SP80H Specification

Stylus carrying capability

Due to the different orientation of the kinematics problems can occur when trying to support heavy styli on SP80H. Failure to reseat properly after the kinematics have been reseated may be observed with styli that have a moment at the stylus root greater than 200 g at 200 mm.

A graph representing a safe working moment range is shown below; this is based upon stylus weight and centre of gravity (COG) distance from the stylus root. It is advised that where possible customers should try and use styli configurations for SP80H that fall within these guidelines.

SP80H stylus carrying capability

SP80H stylus carrying capability

SP80H probe specification

The probe orientation shown below is the orientation used in the SP80H probe product specification.

 

SP80H orientation

Probe coordinate system for SP80H specification

SP80H probe system specification

ParameterDescription
Probe attributesUltra-high accuracy scanning probe with three axis measurement (±PX, ±PY, ±PZ) *
OrientationHorizontal
Size80 mm x 80 mm (3.15 in x 3.15 in) body, 150 mm (5.91 in) long including SH80 stylus holder
Quill mountingKM80: 80 mm x 80 mm quill to kinematic SP80 quill mount (standard)
KM6080: 60 mm x 60 mm to 80 mm x 80 mm kinematic SP80 probe mount (option)
SM80 : Shank mount and other custom made adaptor plates available - contact your Renishaw supplier for details
Measurement range3 axis measurement:
±1.25 mm (PX) *
±2.5 mm (PY, PZ) *
Overtravel rangePY * and PX * protected by breakout of the kinematic joint to the SH80
PZ * has a mechanical bump stop
Resolution of digital scales0.02 μm
Measurement capability test to ISO10360-2 **Typically <1.0 μm Tij with a 60 mm stylus
Scanning capability test to ISO10360-4 **Typically <1.5 μm Tij with a 60 mm stylus
Time for scan = 74 s
Return to zeroApproximately 1% of working deflection
Spring rateApproximately 2.5 N/mm (PX) *
Approximately 1.6 N/mm (PY, PZ) *
Stylus carrying capabilityRenishaw M5 stylus range
Maximum 300 g mass (unbalanced) as per fig. 14 ***
Maximum 500 mm projection #
MassSP80H probe body only: 860 g
SH80 stylus holder: 185 g
KM80 quill mount: 110 g
Pull off force of SH80<20 N when using SCP80V - otherwise approximately 80 N
Probe power supply+9 V to +18 V @ 300 mA maximum DCc
System power supply (including IU80)+5 V ± 0.25 V @ 1 A maximum DC
SP80 probe outputs (X, Y, Z)1.5 V ± 0.25 V p-p. analogue quadrature signal (nominal 2.5 V zero crossing reference)
Interfacing options
  • Using a UCC2 SP80 daughtercard for direct integration
  • Using Renishaw PCI countercard (CC6) and interpolator unit (IU80)
  • Other interface card designed by OEM and used in conjunction with an IU80
  • Using a countercard and interpolator units designed by the OEM
Change rack systemSP80V mounted to on OEM supplied extension

* Where P specifies that it is the probe's axis rather than the machine's.
** Tested on a CMM with specification of 0.48 μm + L/1000 with touch and scanning deflections ≤ 0.15 mm.
*** Stylus centre of gravity to be within area A of graph.
# Longer stylus lengths may be carried subject to operating conditions - consult Renishaw for application assistance